L4R-HPHMDM-SGW
LDF4RK-50 SureFlex® Jumper with interface types 4.3-10 Male and 7-16 Din Male, with HELIAX® SureGuard weatherproofingwith, black non-halogenated fire retardant polyolefin jacket B2ca-S1a-d1-a1
Specifications
Product classification
| Product Type | SureFlex® HP, HELIAX® performance |
| Product Brand | HELIAX® | SureFlex® |
| Product Series | LDF4RK-50 |
General specifications
| Attachment, Connector A | Factory attached |
| Attachment, Connector B | Factory attached |
| Body Style, Connector A | Straight |
| Body Style, Connector B | Straight |
| Interface, Connector A | 4.3-10 Male |
| Interface, Connector B | 7-16 DIN Male |
| Specification Sheet Revision Level | A |
| Variable Length | For custom lengths, contact your local ANDREW representative |
Dimensions
| Cable Assembly Length Range (ft) | 1 – 100 |
| Nominal Size | 1/2 in |
Electrical specifications
| 3rd Order IMD Static Test Method | Two +43 dBm carriers |
| 3rd Order IMD typical | -116 dBm |
| DTF, Connector A | -34 dB |
| DTF, Connector B | -34 dB |
Jumper assembly sample label
| Click on image to enlarge. |
Environmental specifications
| EN50575 CPR Cable EuroClass Fire Performance | B2ca |
| EN50575 CPR Cable EuroClass Smoke Rating | s1a |
| EN50575 CPR Cable EuroClass Droplets Rating | d1 |
| EN50575 CPR Cable EuroClass Acidity Rating | a1 |
| Immersion Test Method | Meets IEC 60529:2001, IP68 in mated condition |
Product classification
| Product Type | SureFlex® HP, HELIAX® performance |
| Product Brand | HELIAX® | SureFlex® |
| Product Series | LDF4RK-50 |
General specifications
| Attachment, Connector A | Factory attached |
| Attachment, Connector B | Factory attached |
| Body Style, Connector A | Straight |
| Body Style, Connector B | Straight |
| Interface, Connector A | 4.3-10 Male |
| Interface, Connector B | 7-16 DIN Male |
| Specification Sheet Revision Level | A |
| Variable Length | For custom lengths, contact your local ANDREW representative |
Dimensions
| Cable Assembly Length Range (ft) | 1 – 100 |
| Nominal Size | 1/2 in |
Electrical specifications
| 3rd Order IMD Static Test Method | Two +43 dBm carriers |
| 3rd Order IMD typical | -116 dBm |
| DTF, Connector A | -34 dB |
| DTF, Connector B | -34 dB |
Environmental specifications
| EN50575 CPR Cable EuroClass Fire Performance | B2ca |
| EN50575 CPR Cable EuroClass Smoke Rating | s1a |
| EN50575 CPR Cable EuroClass Droplets Rating | d1 |
| EN50575 CPR Cable EuroClass Acidity Rating | a1 |
| Immersion Test Method | Meets IEC 60529:2001, IP68 in mated condition |
| Click on image to enlarge. |
Installation & videos
Installation instruction
Documentation & downloads