Warning Icon

For other alternatives, please contact us for more information.

0 Alternative products available

MPTE02EBBBNN

  • Available in:
  • Europe

HELIAX® Power cable, White & Red with aluminum drain wire & shield with 2x35 mm2 cores, flame resistant CPR Class B2ca s1a, d2, a1 rated, 500 meters

Finish making your selections or clear them to view relevant specifications.
Download specifications
Features and benefits
Rated voltage: AC: 0.6/1 kV (1,2 kV) DC: 0.9/1.5 kV.Operating Voltage 48 VDC. Test voltage: 8,4 KV DC for 5min. Aluminum drain wire 2x12mm². Shielding Resistance 1.21 (Ohm/km).

Product classification

Regional Availability Europe
Product Type Power cable
Product Brand HELIAX®
Ordering Note ANDREW® non-standard product

General specifications

Application Remote radio head
Cable Type Power
Conductor Type, singles Stranded
Conductors, quantity 2
Construction Type Discrete power cable
Drain Wire Type Stranded
Drain Wire, quantity 2
Jacket Color Black
Jacket Color, singles Red | White
Outer Shield (Tape) Material Al/PET tape

Dimensions

Cable Length 500.024 m | 1640.5 ft
Diameter Over Jacket 21.200 mm | 0.8346457 in
Conductor Gauge 35 mm² class 5

Electrical specifications

Conductor dc Resistance Note Maximum value based on a standard condition of 20 °C (68 °F)
Safety Voltage Rating 900 V

Material specifications

Ground Wire Material Annealed aluminum wires
Jacket Material Flame retardant PE
Outer Shield (Tape) Material Al/PET tape

Environmental specifications

Installation temperature -40 °C to +80 °C (-40 °F to +176 °F)
EN50575 CPR Cable EuroClass Fire Performance B2ca
EN50575 CPR Cable EuroClass Smoke Rating s1a
EN50575 CPR Cable EuroClass Droplets Rating d2
EN50575 CPR Cable EuroClass Acidity Rating a1
Environmental Space Indoor/Outdoor
Jacket UV Resistance UV stabilized

Packaging and weights

Cable weight 836.000 kg/km | 561.766 lb/kft

Product classification

Regional Availability Europe
Product Type Power cable
Product Brand HELIAX®
Ordering Note ANDREW® non-standard product

General specifications

Application Remote radio head
Cable Type Power
Conductor Type, singles Stranded
Conductors, quantity 2
Construction Type Discrete power cable
Drain Wire Type Stranded
Drain Wire, quantity 2
Jacket Color Black
Jacket Color, singles Red | White
Outer Shield (Tape) Material Al/PET tape

Dimensions

Cable Length 500.024 m | 1640.5 ft
Diameter Over Jacket 21.200 mm | 0.8346457 in
Conductor Gauge 35 mm² class 5

Electrical specifications

Conductor dc Resistance Note Maximum value based on a standard condition of 20 °C (68 °F)
Safety Voltage Rating 900 V

Material specifications

Ground Wire Material Annealed aluminum wires
Jacket Material Flame retardant PE
Outer Shield (Tape) Material Al/PET tape

Environmental specifications

Installation temperature -40 °C to +80 °C (-40 °F to +176 °F)
EN50575 CPR Cable EuroClass Fire Performance B2ca
EN50575 CPR Cable EuroClass Smoke Rating s1a
EN50575 CPR Cable EuroClass Droplets Rating d2
EN50575 CPR Cable EuroClass Acidity Rating a1
Environmental Space Indoor/Outdoor
Jacket UV Resistance UV stabilized

Packaging and weights

Cable weight 836.000 kg/km | 561.766 lb/kft

Product specification

Product specification